MICROBIOLOGY LABORATORY SERVICES
Fully accredited by the American Industrial Hygiene Association (AIHA) for Environmental Microbiology (Lab ID#: 100951). All supplies required for the following tests can be ordered from Micro Air, Inc.
AIR TESTING
Direct Spore Trap Analysis
Used for the identification and enumeration of viable and non-viable airborne mold spores within a defined space. Samples are collected using a direct spore trap cassette (i.e. the Air-O-CellTM) that is specifically designed for rapid collection and analysis.
Method of Analysis: Method M01, Revision 3
Turnaround Times Available: 24-Hour and 3 Day
Air-O-CellTM Cassette Sampling Information
Viable Air Mold or Bacteria Sample Testing
Used for identification and enumeration of airborne viable mold spores or bacteria within a defined space. Samples can be taken using an Anderson Viable Impact Sampler or a SAS Super90 Sampler. Results are reported in CFU/m3.
Method of Analysis: Method M02, Procedure 1 for Mold, Revision 3
Method M03, Procedure 1 for Bacteria, Revision 3
Turnaround Times Available: 5-10 Days
Viable Air Speciation of Mold or Bacteria
Micro Air, Inc. is able to speciate mold or bacteria using traditional methods and the BIOLOG System.
Method of Analysis: Method MI01 for Filamentous Fungi
Method MI02 for Gram Negative Bacteria
Method MI03 for Gram Positive Bacteria
Turnaround Times Available: 10-30 Days
SURFACE AND BULK TESTING
Tape for Surface Mold
Used for identification and enumeration of genus mold present on a surface. Samples can be taken using a Bio-TapeTM for standardized surface sampling. Traditional non-frosted tape can also be used.
Method of Analysis: Method M08, Revision 3
Turnaround Times Available: 24 Hour and 3 Day
Bio-TapeTM Sampling Instructions
Viable RODAC Testing for Mold or Bacteria
Used for identification and enumeration of airborne viable mold spores or bacteria within a defined space. A RODAC, or Replicate Organism Detection and Counting, plate is used to collect viable mold or bacteria from surface onto a media that can be used to identify and enumerate the mold or bacteria present. Results are reported in CFU/in2.
Method of Analysis: Method M02, Procedure 2 for Mold, Revision 3
Method M03, Procedure 2 for Bacteria, Revision 3
Turnaround Times Available: 5-10 Days
Bulk Materials Testing for Mold or Bacteria
Used for identification and enumeration of mold or bacteria present on or within a bulk material. Samples can be transported in their original material to the laboratory for analysis.
Method of Analysis: Method M09 for Mold, Revision 3
Method M10 for Bacteria, Revision 3
Turnaround Times Available: 5-10 Days
Viable Surface Swab Testing for Mold or Bacteria
Used for identification and enumeration of viable mold or bacteria present within a defined space. Samples are taken with a sterile swab in a non-destructive way.
Method of Analysis: Method M04 for Mold, Revision 3
Method M06 for Bacteria, Revision 3
Turnaround Times Available: 5-10 Days
Surface Swab Sampling Instructions
Non-Viable Surface Swab Testing for Mold or Bacteria
Used for identification and enumeration of non-viable mold or bacteria present within a defined space. Samples are taken with a sterile swab in a non-destructive way.
Method of Analysis: Method M05 for Mold, Revision 3
Method M07 for Bacteria, Revision 3
Turnaround Times Available: 24 Hour and 3 Day
Surface Swab Sampling Instructions